Rack-mounting Shielding Box

Views:2273+ Collection:9+

* Adopt 19" standard plug-in box design
* Adopts drawable and flip design
* Provide DC power filter, with maximum support of 7.5A

Download the technical specifications of product series

Specification
  • RSB-2U8R
  • RSB-C601
  • RSB-C601
  • RSB-C601
  • RSB-C601
  • RSB-C601
  • RSB-C601
  • RSB-C601
  • RSB-C601
  • RSB-C601
  • RSB-C601
  • RFA-C601
  • RFA-C601
  • RFA-C601
  • TCD-C000
  • TCD-C000
  • TCD-C000
  • TCD-C000
  • TCD-C000
  • TCD-C000
  • TCD-C000
  • TCD-C000
Quantity
Payment method
100% payment in advance

Related recommendation

Description

Freq.range

(MHz)

Isolation

(dB)

I/O Interface*

Dimensions (mm)

(WxHxD)

Weight 

(kg)

RF Connector**
2U UE MIMO box700~800060USB3.0482 x 88 x 35010SMA-Female *8
2U Draw-out shielding box series700~6000

700MHz-2GHz>65dB

2GHz-4GHz>60dB

4GHz-6GHz>55dB

USB2.0

RJ45/1Gbps

DC 7.5A

482 x 88 x 36015SMA-Female *16
3U Draw-out shielding box series700~6000

700MHz-2GHz>65dB

2GHz-4GHz>60dB

4GHz-6GHz>55dB

USB2.0

RJ45/1Gbps

DC 7.5A

482 x 132 x 36020SMA-Female *16
4U Draw-out shielding box series700~6000

700MHz-2GHz>65dB

2GHz-4GHz>60dB

4GHz-6GHz>55dB

USB2.0

RJ45/1Gbps

DC 7.5A

482 x 176 x 36020SMA-Female *16
6U shielding box series700~6000

0.7GHz-6GHz>70dB

6GHz-8.5GHz>65dB


USB3.0

RJ45/1Gbps

DC 7.5A

AC 10A

482 x 262 x 45015

SMA-Female *8

N-Female *4

8U shielding box series700~600070

USB3.0

RJ45/1Gbps

DC 7.5A

AC 10A

482 x 350 x 56518

SMA-Female *8

N-Female *8


* I/O Interfaces are optional

** Qty and type of RF connectors could be customized.


Part NumberModelDescription
31000737RSB-2U8RDU2U UE MIMO box with 2 sub shielding space, USB3.0 x 2
31000045RSB-C601-0053U Draw-out shielding box with 4 sub shielding space, USB2.0 x 8
31000072RSB-C601-0183U Draw-out shielding box with 4 sub shielding space, USB3.0 x 8
31000042RSB-C601-0033U Draw-out shielding box with 6 sub shielding space, USB2.0 x 6
31000052RSB-C601-0113U Draw-out shielding box with 6 sub shielding space, USB3.0 x 6
31000054RSB-C601-0103U Draw-out shielding box with USB2.0 x 12
31000155RSB-C601-0474U Draw-out shielding box with USB2.0 x8, cooling fan x 2
31000762RSB-C601-078Shielding Box,19”,6U,450
31000118RSB-C601-032Shielding Box,19”,8U,565
31000774RSB-C601-080

4 Subsections UE Shielding Box with 4x honeycomb filter

(3U UE box dummy panel, without isolation board)

31000775RSB-C601-081

2 Subsections UE Shielding Box with 2x honeycomb filter

(2U UE box dummy panel)

30600153RFA-C601-025Filter, LAN, DC, USB2.0
30600180RFA-C601-044Filter, LAN, DC, USB3.0
30600890RFA-C601-136Filter, LAN, DC, USB-C
31500303TCD-C000-034Cover panel(replace signal filter)
31500304TCD-C000-035DC Cooling fan outlet(Two filter height)
31500427TCD-C000-036DC Cooling fan inlet(Two filter height)
31501156TCD-C000-043Honeycomb filter
31501157TCD-C000-044Partition with honeycomb for 3U UE Shielding Box (Plus) only
31501158TCD-C000-045DC FAN Assembly, inlet
31501159TCD-C000-046DC FAN Assembly, outlet

The main function of the shielding box is to shield electromagnetic waves, so that external electromagnetic waves cannot enter the shield box and affect the test, so as to prevent the signal in the shield box from leaking to the shield box, so as to ensure the normal operation of the test equipment inside and outside the shield box. It is widely used in the performance test scenario from base station to UE in cellular network, such as UMTS, LTE,5GNR.

image.png

No data